Soft-start a DC motor

Problem Advanced New no attempts yet
A 48 V DC motor drives a conveyor with a heavy drum (inertia $5\ \text{kg·m}^2$) against a load torque of $5\ \text{N·m}$. Its winding has only $0.2\ Ω$ of resistance.

A spinning motor is also a generator: it makes a back-EMF $e = k\,\omega$ that opposes the supply. The current is set by what is left over: $I = \frac{V - k\omega}{R}$. At standstill there is no back-EMF, so switched straight onto 48 V the motor would draw $48/0.2 = 240\ \text{A}$, enough to blow the drive's fuses.

The drive can instead ramp the voltage up gently, so the back-EMF keeps up with it. The motor's torque is $kI$, and it speeds up by $\frac{kI - T_{load}}{J}$ every second.

How to do it:
1. Press Play with the starting ramp (48 V per second): see the current spike far above 60 A.
2. During a ramp the current is roughly 20 × ramp + 10 amps (see the explanation). Solve 20 × ramp + 10 ≤ 60.
3. Set the ramp at or below your limit, but not so slow that the motor is still slow at 40 s.
4. Press Play, check both graphs against their dashed lines, then press Check my answer.
Question
What ramp rate keeps the current at or under 60 A, yet has the motor at 85 rad/s or more after 40 seconds?

Join free to take this activity

Anyone can look around, but taking an activity needs a free account. With one, your answers are checked step by step and your progress is saved, so you can stop and pick up where you left off on any device.

It is part of the course Electrical engineering: from first circuits to the power grid.

Nobody has tried this yet.Be the first. Your answer starts the stats.

Only each person's first answer, given before viewing the solution, is counted.

Discussion 0 comments

Log in to join the discussion.

× Enlarged view