Omniadisce

Why engineers add safety factors

Lesson Beginner

Join free to take this lesson

Anyone can look around, but taking a lesson needs a free account. With one, your answers are checked step by step and your progress is saved, so you can stop and pick up where you left off on any device.

5 steps ยท about 12 min ยท runs in the Beam lab

No one knows exactly what a floor will carry. Engineers plan for bad luck.

The idea

Loads are uncertain and materials vary. Eurocodes deal with this with partial factors: the design load is bigger than the expected one, and the design strength smaller than the measured one.

Ultimate limit state (EN 1990, eq. 6.10): $w_{Ed} = 1.35\,G + 1.5\,Q$

Permanent load G (self-weight, finishes) is well known, so its factor is smaller than for variable load Q (people, furniture, snow).

By the end you can

  • Permanent load G is always there and well known; variable load Q comes and goes.
  • Engineers design for the design load: $w_{Ed} = 1.35 G + 1.5 Q$.
  • The less predictable load gets the bigger safety factor.
  • Design moments use the design load: $M_{Ed} = w_{Ed} L^2 / 8$.

Discussion 0 comments

Log in to join the discussion.

× Enlarged view