Omniadisce

Beam calculator: steel and timber

Choose the supports, the section and the loads. The calculator finds the reactions, draws the shear force and bending moment diagrams, and checks bending, shear and deflection to Eurocode 3 (steel) or Eurocode 5 (timber).

Learn how this works
Beam
Loads
All 3 checks pass. The worst is at 42% of its limit.

Results

Reaction at 0 m (ULS)16.82 kN
Reaction at 6 m (ULS)16.82 kN
Largest bending moment (ULS)36.48 kNm
Largest shear force (ULS)16.82 kN
Largest deflection (service loads)10.3 mm
Beam mass184 kg
Shear force V (ULS) (largest 16.8 kN at 0 m)
0 m6 m
Bending moment M (ULS) (largest 36.5 kNm at 3 m)
0 m6 m
Deflection (service loads) (largest -10.3 mm at 3 m)
0 m6 m

Checks

  • Bending resistance 42%

    EN 1993-1-1 6.2.5 ยท 36.48 against 86.245 kNm

    M_Rd = W_pl ยท f_y / ฮณ_M0

    M_Rd = 367 cmยณ ร— 235 MPa / 1.0 = 86.2 kNm. The largest moment is M_Ed = 36.5 kNm at x = 3.00 m.

    The whole cross-section can yield before the beam forms a hinge: this is its bending strength.

  • Shear resistance 6%

    EN 1993-1-1 6.2.6 ยท 16.82 against 259.518 kN

    V_Rd = A_v ยท (f_y / โˆš3) / ฮณ_M0

    V_Rd = 19.1 cmยฒ ร— (235 / โˆš3) MPa = 259.5 kN. The largest shear is V_Ed = 16.8 kN at x = 0.00 m.

    The web carries the shear; steel yields in shear at f_y / โˆš3.

  • Deflection, Span 0โ€“6 m 42%

    EN 1990 A1.4 (limit L/250) ยท 10.257 against 24 mm

    ฮด โ‰ค L / 250 (an overhang counts double)

    Limit = 6.00 m / 250 = 24.0 mm; the beam sags 10.3 mm. Stiffness EยทI = 210 GPa ร— 3892 cmโด.

    Too much sag cracks finishes and feels unsafe, even when the beam is strong enough. Deflection grows with the span to the fourth power (5 w Lโด / 384 E I).

Key formulas

Ultimate load (EN 1990 6.10)
w = 1.35 G + 1.5 Q
Simply supported, uniform load
M_max = w Lยฒ / 8, V_max = w L / 2, ฮด_max = 5 w Lโด / (384 E I)
Bending resistance (EN 1993-1-1 6.2.5)
M_Rd = W_pl f_y / ฮณ_M0
Shear resistance (EN 1993-1-1 6.2.6)
V_Rd = A_v (f_y / โˆš3) / ฮณ_M0
Assumptions
  • ULS: 1.35 G + 1.5 Q (EN 1990 eq. 6.10); variable load acts on every span at once.
  • Compression flange laterally restrained: lateral-torsional buckling not checked.
  • Steel sections treated as class 1 (plastic bending resistance).
  • Characteristic combination G + Q, EN 1990 6.5.3.
Learn how this worksBuild it yourself in the Beam lab, with guided lessons and challenges.