Omniadisce

Flexible pavement design calculator (standard axles, msa)

Enter the heavy traffic, its growth and the design life, the subgrade CBR and the layer thicknesses. The calculator turns the traffic into standard axles and checks the asphalt for fatigue cracking and the subgrade for rutting.

Learn how this works
Traffic
Ground and layers
All 3 checks pass. The worst is at 88% of its limit.

Results

Design traffic15.40 million standard axles
Standard axles per heavy vehicle (mix average)1.929
Growth factor24.30 years of today's traffic
Tensile strain at the bottom of the asphalt ฮต_t195 microstrain
Vertical strain on the subgrade ฮต_v275 microstrain
Fatigue life17.32 msa
Rutting life34.03 msa
Surface deflection under a wheel0.412 mm
Foundation surface modulus99 MPa
Traffic carried (cumulative) (largest 38.3 msa at 40 years)
0 years40 years

Checks

  • Fatigue cracking (bottom of the asphalt) 88%

    Asphalt Institute, field shift factor 10 ยท 15.398 against 17.324 msa

    h_e = 0.9 h (E_ac / E_f)^{1/3}; ฮต_t from Boussinesq at h_e; N_f = 10 ร— 0.0796 ฮต_t^{โˆ’3.291} E^{โˆ’0.854}

    200 mm of asphalt (E = 3500 MPa) on a foundation of surface modulus 99 MPa acts like 592 mm of foundation: ฮต_t = 195 ยตฮต, allowing 17.3 msa; the road will carry 15.4 msa in 20 years.

    Every wheel bends the asphalt; the bottom is stretched and, after millions of repetitions, cracks grow up to the surface (crocodile cracking).

  • Rutting (top of the subgrade) 45%

    Shell subgrade strain criterion (85%) ยท 15.398 against 34.035 msa

    h_e = 0.9 ฮฃ h_i (E_i / E_sg)^{1/3}; ฮต_v from Boussinesq at h_e; N_d = (0.021 / ฮต_v)^4

    All the layers above act like 1188 mm of subgrade (E = 50 MPa): ฮต_v = 275 ยตฮต, allowing 34.0 msa against 15.4 msa.

    Too much pressure on the soil makes it creep under the wheel paths: ruts that hold water and steer cars.

  • A buildable foundation 50%

    surface modulus โ‰ฅ 50 MPa (CD 225 class 1) ยท 50 against 98.582 MPa

    E_foundation from the deflection of sub-base, capping and subgrade under the wheel

    The sub-base, capping and subgrade give a surface modulus of 99 MPa (class 1).

    The asphalt has to be rolled hard on something firm; on a soft foundation it cannot be compacted, and site lorries rut it before the road is even finished.

Key formulas

Fourth-power law
damage per axle = (P / 80 kN)โด
Design traffic
msa = vehicles/day ร— lane share ร— standard axles per vehicle ร— 365 ร— growth factor / 10โถ
Growth factor
((1 + g)^Y โˆ’ 1) / g
Subgrade stiffness
E โ‰ˆ 10 ร— CBR (MPa)
Assumptions
  • Standard axle 80 kN; one wheel of 40 kN at 700 kPa (radius 135 mm); damage โˆ (P/80)โด per axle.
  • Odemark's equivalent thickness with f = 0.9 and Boussinesq on the wheel's axis (Ahlvin and Ulery), ฮฝ = 0.35; a simplification of a full multi-layer elastic analysis.
  • Moduli: subgrade 10 ร— CBR MPa, capping 75, sub-base 150 MPa (each at most 3 ร— the layer below); asphalt at 20 ยฐC.
  • Fatigue: Asphalt Institute with a lab-to-field shift factor of 10; rutting: Shell 85% subgrade strain criterion; no temperature seasons, no ageing. Calibrated to give lives of the same order as UK design charts.
  • Costs per mยฒ including excavation; per km for 10 m of carriageway.
Learn how this worksBuild it yourself in the Pavement lab, with guided lessons and challenges.