A square or rectangular concrete pad under a column, on one soil with a water table. The calculator checks the bearing resistance (EN 1997-1 Annex D, design approach 1) and works out the settlement.
| Footing thickness | 0.60 m |
|---|---|
| Footing self-weight | 128.6 kN |
| Net bearing pressure q_net | 264.7 kPa |
| Bearing at base, drained, DA1-C1 | 2,289 of 5,916 kN |
| Bearing at base, drained, DA1-C2 | 1,809 of 2,825 kN |
| Settlement | 22.5 mm |
EN 1997-1 6.5.2, Annex D ยท 1808.6 against 2824.6 kN
R / A = c' N_c s_c + q' N_q s_q + ยฝ ฮณ' B N_ฮณ s_ฮณ
Governing case: Bearing at base, drained, DA1-C2. Medium dense sand: design ฯ' = 26.6ยฐ (so N_q = 12.6, N_ฮณ = 11.6), c' = 0.0 kPa, overburden q' = 18.0 kPa, ฮณ' = 16.7 kN/mยณ, area 2.40 ร 2.40 m: R_d = 2825 kN. Design load 1809 kN.
Friction on the grains carries the load; the soil above the base (q') and the footing width both help, and water lowers both by reducing the effective stress.
limit 25 mm (EN 1997-1 Annex H) ยท 22.5 against 25 mm
s = ฮฃ ฮฯ ฮz / E (sand, gravel) + ฮฃ ฮz C_c / (1 + e_0) ยท log((ฯ'_0 + ฮฯ) / ฯ'_p) (clay)
Net pressure 265 kPa spreads into the ground (Boussinesq). Immediate settlement 22.5 mm, clay consolidation 0.0 mm: 22.5 mm against 25 mm.
Clay squeezes water out slowly and keeps settling for years; sand settles at once and little.