A simply supported rectangular beam with bottom bars and shear links. The calculator checks bending, ductility, minimum and maximum steel, shear, links, deflection by the span/depth rule, crack control and whether the bars fit.
| Design load w (ULS, with self-weight) | 40.82 kN/m |
|---|---|
| Design moment M_Ed | 183.68 kNm |
| Moment resistance M_Rd | 245.01 kNm |
| Design shear at the support V_Ed | 122.46 kN |
| Effective depth d | 502 mm |
| Steel area A_s | 1,257 mmยฒ |
| Neutral axis depth x | 134 mm |
| Lever arm z | 448 mm |
| Cracking moment M_cr | 43.81 kNm |
| Shear resistance without links V_Rd,c | 86.2 kN |
| Shear resistance of the links V_Rd,s | 246.8 kN |
EN 1992-1-1 6.1 ยท 183.684 against 245.009 kNm
M_Rd = A_s f_yd (d โ 0.4 x), x = A_s f_yd / (0.8 b f_cd)
A_s = 4 ร โ20 = 1257 mmยฒ, f_yd = 500 / 1.15 = 435 MPa, f_cd = 0.85 ร 30 / 1.5 = 17.0 MPa; d = 502 mm, x = 134 mm, lever arm z = 448 mm: M_Rd = 245.0 kNm against M_Ed = w Lยฒ/8 = 40.8 ร 6ยฒ / 8 = 183.7 kNm.
Concrete takes the compression at the top, the bars the tension at the bottom; their forces form a couple with lever arm z.
EN 1992-1-1 5.6.3 ยท 0.267 against 0.45
x / d โค 0.45
Neutral axis x = 134 mm, d = 502 mm: x / d = 0.27. When the concrete reaches ฮต_cu = 0.0035 the steel strain is ฮต_cu (d โ x) / x = 0.0096, against 0.0022 to yield.
With too much steel the concrete crushes before the bars yield: a sudden, brittle failure with no warning.
EN 1992-1-1 9.2.1.1 ยท 226.828 against 1256.64 mmยฒ
A_s โฅ max(0.26 f_ctm / f_yk, 0.0013) b d
A_s,min = max(0.26 ร 2.90 / 500, 0.0013) ร 300 ร 502 = 227 mmยฒ; provided 1257 mmยฒ.
When the concrete cracks, the steel must be able to take over the tension the concrete was carrying.
EN 1992-1-1 6.2 ยท 101.965 against 246.847 kN
V_Rd,s = (A_sw / s) z f_ywd cot ฮธ โค V_Rd,max; without links V_Rd,c = C k (100 ฯ f_ck)^{1/3} b d
V_Ed at d from the support = 102.0 kN. Concrete alone: V_Rd,c = 86.2 kN; links โ8 (2 legs) at 200 mm: V_Rd,s = 246.8 kN (z = 0.9 d, cot ฮธ = 2.5); the concrete struts limit V_Rd,max = 419.5 kN.
Near the supports the beam cracks diagonally; links stitch those cracks. Shear failure is sudden, so it must never govern.
EN 1992-1-1 9.2.2 ยท 0.876 against 1.676 โฐ
ฯ_w = A_sw / (s b) โฅ 0.08 โf_ck / f_yk
ฯ_w = 101 / (200 ร 300) = 1.68โฐ against 0.88โฐ. Spacing also at most 0.75 d = 376 mm.
Every beam needs a minimum cage so that a first diagonal crack does not split it.
EN 1992-1-1 7.4.2 ยท 11.952 against 24.589
L / d โค K [11 + 1.5 โf_ck ฯโ/ฯ + 3.2 โf_ck (ฯโ/ฯ โ 1)^{3/2}] ร 310 / ฯ_s
ฯ = 0.83%, ฯโ = 0.55%: allowed L/d = 24.6; this beam has 6000 / 502 = 12.0.
Rather than computing sag, the code limits slenderness: lightly reinforced beams may be more slender.
EN 1992-1-1 7.3.3 ยท 68 against 279.15 mm
bar spacing โค s_max(ฯ_s) for w_k = 0.3 mm (table 7.3N)
Steel stress under quasi-permanent load ฯ_s โ 177 MPa allows 279 mm; bars are 68 mm apart.
Many small, well-spread bars give many fine cracks instead of a few wide ones that let water reach the steel.
EN 1992-1-1 8.2 ยท 231 against 300 mm
n ฯ + (n โ 1) max(ฯ, 25) + 2 (cover + link) โค b
4 ร 20 + 3 ร 25 + 2 ร (30 + 8) = 231 mm in a 300 mm beam.
Concrete has to flow between the bars and round them, and the vibrator has to get in.