Omniadisce

Reinforced concrete beam calculator (Eurocode 2)

A simply supported rectangular beam with bottom bars and shear links. The calculator checks bending, ductility, minimum and maximum steel, shear, links, deflection by the span/depth rule, crack control and whether the bars fit.

Learn how this works
Beam
Steel
Loads
All 8 checks pass. The worst is at 77% of its limit.

Results

Design load w (ULS, with self-weight)40.82 kN/m
Design moment M_Ed183.68 kNm
Moment resistance M_Rd245.01 kNm
Design shear at the support V_Ed122.46 kN
Effective depth d502 mm
Steel area A_s1,257 mmยฒ
Neutral axis depth x134 mm
Lever arm z448 mm
Cracking moment M_cr43.81 kNm
Shear resistance without links V_Rd,c86.2 kN
Shear resistance of the links V_Rd,s246.8 kN

Checks

  • Bending resistance 75%

    EN 1992-1-1 6.1 ยท 183.684 against 245.009 kNm

    M_Rd = A_s f_yd (d โˆ’ 0.4 x), x = A_s f_yd / (0.8 b f_cd)

    A_s = 4 ร— โŒ€20 = 1257 mmยฒ, f_yd = 500 / 1.15 = 435 MPa, f_cd = 0.85 ร— 30 / 1.5 = 17.0 MPa; d = 502 mm, x = 134 mm, lever arm z = 448 mm: M_Rd = 245.0 kNm against M_Ed = w Lยฒ/8 = 40.8 ร— 6ยฒ / 8 = 183.7 kNm.

    Concrete takes the compression at the top, the bars the tension at the bottom; their forces form a couple with lever arm z.

  • Ductility (x / d) 59%

    EN 1992-1-1 5.6.3 ยท 0.267 against 0.45

    x / d โ‰ค 0.45

    Neutral axis x = 134 mm, d = 502 mm: x / d = 0.27. When the concrete reaches ฮต_cu = 0.0035 the steel strain is ฮต_cu (d โˆ’ x) / x = 0.0096, against 0.0022 to yield.

    With too much steel the concrete crushes before the bars yield: a sudden, brittle failure with no warning.

  • Minimum reinforcement 18%

    EN 1992-1-1 9.2.1.1 ยท 226.828 against 1256.64 mmยฒ

    A_s โ‰ฅ max(0.26 f_ctm / f_yk, 0.0013) b d

    A_s,min = max(0.26 ร— 2.90 / 500, 0.0013) ร— 300 ร— 502 = 227 mmยฒ; provided 1257 mmยฒ.

    When the concrete cracks, the steel must be able to take over the tension the concrete was carrying.

  • Shear resistance 41%

    EN 1992-1-1 6.2 ยท 101.965 against 246.847 kN

    V_Rd,s = (A_sw / s) z f_ywd cot ฮธ โ‰ค V_Rd,max; without links V_Rd,c = C k (100 ฯ f_ck)^{1/3} b d

    V_Ed at d from the support = 102.0 kN. Concrete alone: V_Rd,c = 86.2 kN; links โŒ€8 (2 legs) at 200 mm: V_Rd,s = 246.8 kN (z = 0.9 d, cot ฮธ = 2.5); the concrete struts limit V_Rd,max = 419.5 kN.

    Near the supports the beam cracks diagonally; links stitch those cracks. Shear failure is sudden, so it must never govern.

  • Minimum links 53%

    EN 1992-1-1 9.2.2 ยท 0.876 against 1.676 โ€ฐ

    ฯ_w = A_sw / (s b) โ‰ฅ 0.08 โˆšf_ck / f_yk

    ฯ_w = 101 / (200 ร— 300) = 1.68โ€ฐ against 0.88โ€ฐ. Spacing also at most 0.75 d = 376 mm.

    Every beam needs a minimum cage so that a first diagonal crack does not split it.

  • Deflection (span / depth) 48%

    EN 1992-1-1 7.4.2 ยท 11.952 against 24.589

    L / d โ‰ค K [11 + 1.5 โˆšf_ck ฯโ‚€/ฯ + 3.2 โˆšf_ck (ฯโ‚€/ฯ โˆ’ 1)^{3/2}] ร— 310 / ฯƒ_s

    ฯ = 0.83%, ฯโ‚€ = 0.55%: allowed L/d = 24.6; this beam has 6000 / 502 = 12.0.

    Rather than computing sag, the code limits slenderness: lightly reinforced beams may be more slender.

  • Crack control (bar spacing) 24%

    EN 1992-1-1 7.3.3 ยท 68 against 279.15 mm

    bar spacing โ‰ค s_max(ฯƒ_s) for w_k = 0.3 mm (table 7.3N)

    Steel stress under quasi-permanent load ฯƒ_s โ‰ˆ 177 MPa allows 279 mm; bars are 68 mm apart.

    Many small, well-spread bars give many fine cracks instead of a few wide ones that let water reach the steel.

  • Bars fit in one layer 77%

    EN 1992-1-1 8.2 ยท 231 against 300 mm

    n ฯ† + (n โˆ’ 1) max(ฯ†, 25) + 2 (cover + link) โ‰ค b

    4 ร— 20 + 3 ร— 25 + 2 ร— (30 + 8) = 231 mm in a 300 mm beam.

    Concrete has to flow between the bars and round them, and the vibrator has to get in.

Key formulas

Design moment
M_Ed = (1.35 G + 1.5 Q) Lยฒ / 8
Moment resistance (EN 1992-1-1 6.1)
M_Rd = A_s f_yd z, z = d โˆ’ 0.4 x, x = A_s f_yd / (0.8 b f_cd)
Shear with links (EN 1992-1-1 6.2.3)
V_Rd,s = (A_sw / s) z f_ywd cot ฮธ
Deflection (EN 1992-1-1 7.4.2)
L / d โ‰ค K [11 + 1.5 โˆšf_ck ฯโ‚€/ฯ + โ€ฆ]
Assumptions
  • ULS 1.35 G + 1.5 Q; self-weight 25 kN/mยณ; simply supported span.
  • f_cd = 0.85 f_ck / 1.5, f_yd = 500 / 1.15 (B500 steel); rectangular stress block ฮป = 0.8, ฮท = 1.
  • Singly reinforced section; shear with cot ฮธ = 2.5 (ฮธ = 21.8ยฐ).
  • Deflection by the span/depth rule, cracking by the bar-spacing table: no explicit sag or crack-width calculation.
Learn how this worksBuild it yourself in the Concrete lab, with guided lessons and challenges.
× Enlarged view