Omniadisce

Retaining wall calculator: gravity, cantilever and sheet pile

Choose the wall type, the soil it holds back and its dimensions. The calculator works out the Rankine earth pressures and checks the wall to EN 1997-1 design approach 1. Fields that do not apply to the chosen wall type are ignored.

Learn how this works
Wall and ground
Gravity and cantilever walls
Sheet piles
All 6 checks pass. The worst is at 80% of its limit.

Results

Wall typeRC cantilever
Utilisation (worst check)80%
Concrete per metre run2.90 mยณ
Cost per metre runโ‚ฌ1,240

Checks

  • Sliding 80%

    EN 1997-1 6.5.3, DA1-C2 ยท 103.058 against 128.203 kN/m

    H_d โ‰ค V_d tan ฮด_d, ฮด = ฯ†'_foundation; P_a = ยฝ K_a ฮณ hยฒ + K_a q h

    K_a = 0.382 (ฯ†'_d = 26.6ยฐ, ฮฒ = 0ยฐ) on a 4.80 m virtual back: soil 79 kN/m, surcharge 18 kN/m; design push H_d = 103 kN/m against V tan ฮด = 256 ร— tan 26.6ยฐ = 128 kN/m.

    The soil behind pushes the wall forwards; only friction under the base holds it back, and that friction grows with the weight on the base.

  • Overturning 45%

    EN 1997-1 2.4.7.2 (EQU) ยท 205.439 against 452.753 kNm/m

    M_dst,d โ‰ค M_stb,d about the toe (0.9 stabilising, 1.1 / 1.5 destabilising, tan ฯ† / 1.25)

    Overturning moment 205 kNm/m against restoring 453 kNm/m from the wall and the soil it carries.

    The earth pressure, acting about a third of the way up, tries to tip the wall over its toe.

  • Bearing 71%

    EN 1997-1 Annex D, DA1-C2 ยท 285.06 against 397.4 kN/m

    R/B' = q' N_q i_q + ยฝ ฮณ' B' N_ฮณ i_ฮณ, B' = B โˆ’ 2e, i_q = (1 โˆ’ H/V)ยฒ

    V = 285 kN/m with H = 103 kN/m at e = 0.35 m: effective width B' = 2.70 m, N_q = 12.6, i_q = 0.41: R = 397 kN/m.

    The load is inclined and off-centre: the ground under the toe takes most of it, and inclination lowers the bearing capacity sharply.

  • Resultant in the middle third 36%

    characteristic loads, e โ‰ค B/6 ยท 0.205 against 0.567 m

    e = B/2 โˆ’ ฮฃM/ฮฃV โ‰ค B/6 (no tension under the base)

    Under working loads the resultant is +0.20 m from the centre; B/6 = 0.57 m. Ground pressure 112 kPa at the toe, 52 kPa at the heel.

    Outside the middle third the heel lifts off the ground and the wall starts to rotate forwards.

  • Stem bending 79%

    EN 1992-1-1 6.1, 1 m strip ยท 150.614 against 189.324 kNm/m

    M_Ed = 1.35 M_soil + 1.5 M_surcharge at the stem base; M_Rd = A_s f_yd (d โˆ’ 0.4x)

    M_Ed = 151 kNm/m; โŒ€16 at 150 mm = 1340 mmยฒ/m, d = 342 mm: M_Rd = 189 kNm/m.

    The stem is a vertical cantilever: the bars go on the soil side, where it is in tension.

  • Stem shear 56%

    EN 1992-1-1 6.2.2 (no links) ยท 92.554 against 164.688 kN/m

    V_Ed โ‰ค V_Rd,c = C k (100 ฯ f_ck)^{1/3} b d

    V_Ed = 93 kN/m against V_Rd,c = 165 kN/m.

    Walls have no links, so the concrete alone must carry the shear.

Key formulas

Rankine active pressure
K_a = (1 โˆ’ sin ฯ†') / (1 + sin ฯ†'), ฯƒ_a = K_a (ฮณ z + q)
Passive pressure
K_p = (1 + sin ฯ†') / (1 โˆ’ sin ฯ†')
Sliding
H_d โ‰ค V_d tan ฮด
Overturning (EQU)
M_destabilising โ‰ค M_stabilising
Middle third
e = B/2 โˆ’ xฬ„ โ‰ค B/6
Assumptions
  • Per metre run; Rankine active pressure on the back (on a vertical plane through the heel for cantilevers), parallel to a sloping backfill; no wall friction; passive pressure in front of gravity and cantilever walls ignored.
  • EN 1997-1 DA1: C1 = 1.35 G + 1.5 Q with characteristic soil; C2 = 1.0 G + 1.3 Q with tan ฯ†' / 1.25; EQU for overturning.
  • Undrained backfill: full water pressure behind and triangular uplift under the base; drained: none.
  • Sheet piles: free cantilever, net pressures, embedment +20%; S355, elastic section modulus; no props or anchors.
  • Costs per metre, totals for a 20 m wall.
Learn how this worksBuild it yourself in the Retaining walls lab, with guided lessons and challenges.
× Enlarged view